Features:
●Support Time-of-use Optimization
●AFCI (Optional) &Rapid Shutdown Ready
●Configurable Operation Models
●Build-in Anti-feed-in Function
●Smart Monitoring & Remote Firmware Upgrade
●100% unbalanced output, each phase;200% unbalanced output, each phase (Below 10kW)
Three-phase Hybrid Inverter | |||
Model No. | Price | ||
Support Time-of-use Optimization | PowerLink-5KH3/A | ||
AFCI (Optional) &Rapid Shutdown Ready | PowerLink-8KH3/A | ||
Configurable Operation Models | PowerLink-10KH3/A | ||
Build-in Anti-feed-in Function | PowerLink-12KH3/A | ||
Smart Monitoring & Remote Firmware Upgrade | |||
100% unbalanced output, each phase;200% unbalanced output, each phase (Below 10kW) |
PV Input | PowerLink-5KH3/A | PowerLink-8KH3/A | PowerLink-10KH3/A | PowerLink-12KH3/A |
Max. DC Input Power (kW) | 7.5 | 12 | 15 | 18 |
Max. PV Voltage (V) | 1000 | |||
Rated DC Input Voltage (V) | 620 | |||
DC Input Voltage Range (V) | 150-1000 | |||
MPPT Voltage Range (V) | 150-850 | |||
Full MPPT Range (V) | 200-850 | 300-850 | 200-850 | 500-850 |
Start-up Voltage (V) | 160 | |||
Max. DC Input Current (A) | 20*2A | |||
Max. Short Current (A) | 30*2A | |||
No. of MPPT Trackers / Strings | 2/2 | |||
Battery Port | ||||
Battery Nominal Voltage (V) | 100 | 200 | 250 | 300 |
Battery Voltage Range (V) | 80-600 | 80-600 | 120-650 | 120-650 |
Max. Charge / Discharge Current (A) | 50 | |||
Max. Charge / Discharge Power (kW) | 5 | 8 | 10 | 12 |
Charging Curve | 3 Stages | |||
Compatible Battery Type | Li-ion Battery | |||
AC Grid | ||||
Nominal AC Output Power (kW) | 5 | 8 | 10 | 12 |
Max. AC Input / Output Power (kVA) | 7.5/5.5 | 12/8.8 | 15/11 | 18/13.2 |
Max. AC Output Current (A) | 8.5 | 13.5 | 17 | 21.5 |
Nominal AC Voltage (V) | 230 / 400 | |||
Nominal AC Frequency (Hz) | 50/60 | |||
Power Factor | 1 (-0.8~0.8) | |||
Current THD | <3% | |||
AC Load Output (Back-up) | ||||
Nominal Output Power (VA) | 5000 | 8000 | 10000 | 12000 |
Nominal Output Voltage (V) | 230/400 | |||
Nominal Output Frequency (Hz) | 50/60 | |||
Nominal Output Current (A) | 7.3 | 11.6 | 14.5 | 17.4 |
Peak Output Power | 5500VA,60s | 8800VA,60s | 11000VA,60s | 13200VA,60s |
THDV (with linear load) | <3% | |||
Switching Time | <10ms | |||
Efficiency | ||||
Europe Efficiency | 97.50% | |||
Max. Efficiency | 98.00% | 98.20% | 98.20% | 98.30% |
Battery Charge / Discharge Efficiency | 98.00% | |||
Protection | ||||
Reverse Polarity Protection | Yes | |||
Over Current / Voltage Protection | Yes | |||
Anti-islanding Protection | Yes | |||
AC Short Circuit Protection | Yes | |||
Leakage Current Detection | Yes | |||
Ground Fault Monitoring | Yes | |||
Grid Monitoring | Yes | |||
Enclosure Protect Level | IP65 | |||
General Data | ||||
Dimensions (mm) | 558*535*260 | |||
Weight (kg) | 29 | |||
Topology | Transformerless | |||
Cooling Concept | Intelligent Fan | |||
Relatively Humidity | 0-100% | |||
Operating Temperature Range (℃) | -25~60 | |||
Operating Altitude(m) | <4000 | |||
Noise Emission (dB) | <30 | |||
Standby Consumption(W) | <5 | |||
Display & Communication Interfaces | LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G | |||
Certification & Approvals | NRS097, G98/ G99, EN50549-1, C10/C11, AS4777.2, VDE-AR-N4105, VDE0126, IEC62109-1, IEC62109-2 | |||
EMC | EN61000-6-2, EN61000-6-3 |